1 batches of substandard LED street lamp
December 2nd, learned from the Guangzhou municipal quality and Technical Supervision Bureau, the Bureau recently on the road of the city production areas of lighting product quality supervision and spot checks, a total sample of 3 enterprises produced 3 batches of products, after inspection, 1 enterprises produced 1 batches of the product does not meet the standard requirements.
The supervision and inspection on the basis of GB 7000.5-2005 "road and street lighting safety requirements," GB 7000.1-2007 "lighting part first: General requirements and tests," GB 17743-2007 "of electrical lighting and similar equipment Radio disturbance characteristics limits and methods of measurement," GB 17625.1-2012 "electromagnetic compatibility limits for the harmonic current emission limits (equipment input current is less than or equal to 16A)" and other standards of element structure, external connection and internal wiring, anti shock protection, durability test, dustproof and waterproof, heat resistance, fire resistance and resistance to tracking and other items of inspection.
Main unqualified items and analysis
1, the structure (protection power supply terminal for free wire): the sample of 1 batches of substandard products, mainly for the lamp terminals without positioning or protective measures, according to the standards after a connection to the stranded conductor get off from the terminal, live parts are accessible external metal parts, does not meet the standard request.
2, the structure (shell protection level): this sample has 1 batches of substandard products, mainly for the lighting terminal without waterproof measures, does not meet the standard requirements.
3, dustproof and waterproof unqualified: the sample of 1 batches of substandard products, mainly the lamp is not marked on the IP protection grade, so according to the minimum degree of protection IP outdoor lamp for IP23 inspection, waterproof measures without power supply terminals, there are traces of water, the creepage distance and numerical clearance reduction to the provisions of 3710V, breakdown voltage.
2 batches of energy-saving lamps unqualified
At the same time, the bureau also recently on the production field of general lighting self ballasted fluorescent lamps product quality supervision and spot checks, a total sample of 3 enterprises produced 3 batches of products, by testing 2 production of 2 batches of the product does not meet the standard requirements.
The supervision and inspection on the basis of GB 16844-2008 "general lighting self ballasted fluorescent lamps - Safety requirements," GB/T 17263-2002 "general lighting self ballasted fluorescent lamps Performance requirements," GB 17743-2007 "of electrical lighting and similar equipment Radio disturbance characteristics limits and methods of measurement," GB 17625.1-2012 "electromagnetic compatibility limits of harmonic current emission limits (equipment input current less than 16A)," GB 19044-2003 "general lighting self ballasted fluorescent lamp efficiency limit value and energy efficiency rating", CEL-005 "self ballasted fluorescent lamps for the implementation of energy efficiency labeling rules" and other standards, to sign (safety), interchangeability, to prevent electric shock, mechanical strength and the heat resistance, fire prevention and fire prevention and abnormal state, the lamp power project inspection.
Spot checks found that 1 batches of general lighting with self ballasted fluorescent lamps in the presence of 1 samples of light efficiency is lower than the energy efficiency of the energy efficiency rating of the label. Another batch of product color tolerance project is not qualified, the project refers to the color coordinates of the source and the target color coordinates of the degree of deviation, is a measure of the general lighting of the self ballasted fluorescent color performance of an important indicator. There are many factors that affect the color tolerance of the self ballasted fluorescent lamps, such as the ratio of fluorescent powder and coating process, which may lead to the product color tolerance is greater than 5SDCM.
For more information about LED, please click on China LED network or pay attention to WeChat public account (cnledw2013).
Contact: mack
Phone: 13332979793
E-mail: mack@archled.net
Add: 3rd Floor, Building A, Mingjinhai Second Industrial Zone, Shiyan Street, Baoan, Shenzhen,Guangdong,China